Medizinische Klinik II: Klinik für Kardiologie, Rhythmologie und Internistische Intensivmedizin

Out-patient operations

Service Number of cases OPS number Info
Measurement of the electrical activity of the heart without a tube (catheter) inserted into the heart via an artery not specified 1-266.0
Measurement of the electrical activity of the heart without a tube (catheter) inserted into the heart via an artery 6 1-266.1
Examination of the right side of the heart with a tube (catheter) inserted into the heart via a vein not specified 1-273.1
Examination of the left side of the heart with a tube (catheter) inserted into the heart via an artery 154 1-275.0
Examination of the left side of the heart with a tube (catheter) inserted into the heart via an artery 19 1-275.1
Examination of the left side of the heart with a tube (catheter) inserted into the heart via an artery 35 1-275.2
Examination of the left side of the heart with a tube (catheter) inserted into the heart via an artery not specified 1-275.5
Other investigations of the heart or blood vessels by means of a tube (catheter) 11 1-279.a
Comprehensive ultrasound examination of the heart (echocardiography) by attaching the ultrasound transponder to the chest wall (transthoracic) during physical exercise not specified 3-031
Ultrasound of the heart (echocardiography) through the oesophagus - TEE 5 3-052
Ultrasound scanning of the blood vessels after the insertion of an ultrasound probe into the vessels 4 3-05g.x
X-rays of the arteries in the pelvis with contrast medium 6 3-605
X-rays of the veins in the neck and chest with contrast medium not specified 3-611.2
Removal, exchange or correction of a pacemaker or defibrillator not specified 5-378.01
Removal, exchange or correction of a pacemaker or defibrillator not specified 5-378.07
Removal, exchange or correction of a pacemaker or defibrillator not specified 5-378.51
Removal, exchange or correction of a pacemaker or defibrillator not specified 5-378.52
Removal, exchange or correction of a pacemaker or defibrillator not specified 5-378.5c
Removal, exchange or correction of a pacemaker or defibrillator not specified 5-378.5f
Removal, exchange or correction of a pacemaker or defibrillator not specified 5-378.62
Type of material used for tissue replacement and tissue reinforcement not specified 5-932.12
Use of a cardiac pacemaker that can be used in a magnetic resonance tomography unit not specified 5-934.0
Additional information on materials used 8 8-83b.c6
Intensive care monitoring of respiration, the heart and the circulation without measurement of the pressure in the pulmonary artery and in the right atrium of the heart 28 8-930
not specified 9-984.6
not specified 9-984.7